← all systems · see it in The System
Ideal clock
A clock that 'measures the proper time' along its path: under the clock hypothesis 'the rate at which a clock is affected by time dilation does not depend on its acceleration but only on its instantaneous velocity'; a clock is 'any reference device with uniform periodicity'.
Properties published scienceour proposal
Sourced fields, and our own readings.
| boundary | Inside: a uniform periodic process and the count of its periods along the clock's own world line (its proper time). Outside: the lattice of other clocks it is compared with, the gravitational field it sits in, and the people who read and correct it. |
| nested level | Field scale, rung 1, below the first fold. The unit of a clock lattice; realised by decays and atomic transitions. |
| scale | field |
Measures (7) published science
| characteristic clock: the muon mean lifetime at rest (laboratory value) | 2.197 microseconds |
| CERN storage ring: gamma; dilated lifetime; agreement | 29.327; 64.378 microseconds; 0.9 +/- 0.4 parts per thousand mixed |
| cosmic-ray muons at 98% of c | about five times longer lifetime factor |
| clock lag aboard the ISS | approximately 0.01 s per 12 Earth months s/yr |
| Hafele-Keating flown caesium clocks | 1971 year |
| hydrogen maser redshift test | 1976 year |
| proper time read by an ideal clock | tau = integral over P of sqrt(dt^2 - dx^2/c^2 - dy^2/c^2 - dz^2/c^2) formula |
Cross-scale patterns seen here (3) our proposal
Shapes that recur when the same kind of problem is solved at different scales, and how each shows in Ideal clock. Each links to every other system that shows it.
- same role, different builds (structural)
One role, keeping proper time, built by a weak decay (the muon: 'the clock is the time taken by processes leading to muon decay') and by atomic transitions (caesium clocks, hydrogen masers). - same shape, opposite sign (partial)
Clocks and rods mirror each other between frames: the moving clock's interval is longer by gamma, the moving rod's length shorter by gamma ('Delta x' = Delta x / gamma'). - templating (partial)
Every ideal clock reads the same quantity, the proper-time arclength of its world line, whatever it is made of.
Valence: what it trades, and with whom (9) published science
Each exchange with a neighbour, read from both sides: who gains, who pays, and what carries it.
- Gravitational field via sys:gravitational-field · Ideal clock mixed
- Muon via sys:weak-field · Ideal clock gain
- World line via sys:spacetime · Ideal clock gain
- Lattice of synchronized clocks via sys:spacetime · Ideal clock even
- Measuring rod via sys:spacetime · Ideal clock even
- Instantaneous (momentarily comoving) rest frame via sys:spacetime · Ideal clock gain
- Time dilation via sys:electromagnetic-field · Ideal clock mixed
- Local position invariance via sys:electromagnetic-field · Ideal clock even
- Coordinate time via sys:spacetime · Ideal clock even
Partners and parts published science
Built from / builds (6)
- Lattice of synchronized clocks
- Laboratory frame
- World line
- Proper time (its parameter)
- Einstein synchronisation
- Local position invariance
Sits inside / holds (2)
expressed by (1)
floor filled by (17)
- Lattice of synchronized clocks
- Proper reference frame
- Laboratory frame
- Gravitational field
- Earth
- Muon
- World line
- Measuring rod
- Atomic clock
- Instantaneous (momentarily comoving) rest frame
- Proper time (its parameter)
- Hydrogen maser
- Einstein synchronisation
- Time dilation
- Local position invariance
- Gravitational time dilation
- Coordinate time
represents (1)
Kinds (1)
wired (3)
Notes published science
- A muon in a ring at gamma = 29.327 is the textbook ideal clock: its decay timed its proper time to 0.9 parts per thousand while being bent round a circle.
- Clocks on the ISS lag about 0.01 s per year; GPS must correct for the same effect to work at all.
- Einstein's clock hypothesis was never stated in 1905, only assumed; it became an axiom after accelerators tested it.
- 'Ideal clocks at rest on the geoid of the rotating earth all beat at the same rate' (Ashby 2003), so a clock carried slowly along the geoid picks up no gravitational rate difference.
Layers
The ways it takes in its world, where they meet, and how it acts back, each from L1 (where it meets the world) up.
atomic clocks (electromagnetic field)
- L1: Atomic clocks: thought-experiment clocks 'in practice are replaced by a much more complicated and indirect metrology that is connected to the nature of the vacuum, and uses atomic clocks that operate according to the Standard Model'
- L2: Flown clocks: Hafele and Keating (1971) 'flew caesium atomic clocks east and west around the Earth in commercial airliners, to compare the elapsed time against that of a clock that remained at the U.S. Naval Observatory'; height and speed act in opposite directions
- L3: Redshift read by clocks: 'The most precise measurement was done in 1976 by flying a hydrogen maser and comparing it to one on the ground'; 'The Global Positioning System requires compensation for this redshift to give accurate position values'
ideal clock (own: reads proper time along its world line)
- L1: A periodic process carried along a world line: a clock is 'any reference device with uniform periodicity'; 'in relativity every object is imagined to have its own proper clock and moving clocks run slower'
- L2: Reads proper time: 'a clock moving along a path P measures the proper time, defined by tau = integral over P of sqrt(dt^2 - dx^2/c^2 - dy^2/c^2 - dz^2/c^2)'
- L3: Unaffected by acceleration (the clock hypothesis): 'the rate at which a clock is affected by time dilation does not depend on its acceleration but only on its instantaneous velocity'; implicit in Einstein 1905, now 'usually included in the axioms of special relativity, especially in light of experimental verification up to very high accelerations in particle accelerators'
- L4: Read against the lattice: 'one should envision an inertial reference frame thickly populated with identical, synchronized clocks. As a moving clock travels through this array, its reading at any particular point is compared with a stationary clock at the same point'; a light-clock at rest gives t_A = 2L/c
- L5: Gravity: real clocks 'must be corrected for gravitational time dilation'; at the ISS clocks lag 'approximately 0.01 seconds for every 12 Earth months'; 'For GPS satellites to work, they must adjust for similar bending of spacetime'
muon decay as a clock (weak field)
- L1: Decay as the clock: 'the clock is the time taken by processes leading to muon decay'; 'the muon lifetime at rest as the laboratory value of 2.197 microseconds'
- L2: In flight: cosmic-ray muons at 98% of c live 'about five times longer, in agreement with observations'; Rossi and Hall (1941) 'compared the population of cosmic-ray-produced muons at the top of a mountain to that observed at sea level'
- L3: Accelerated and still ideal: in the CERN muon storage ring 'the lifetime of muons circulating with gamma = 29.327 was found to be dilated to 64.378 microseconds, confirming time dilation to an accuracy of 0.9 +/- 0.4 parts per thousand' (Bailey et al. 1977): a clock on a circular path keeps proper time
Who fills each layer
- L1: Time dilation
- L2: Coordinate time, Time dilation
- L3: Instantaneous (momentarily comoving) rest frame, Time dilation
- L5: Local position invariance
Sources (9) published science
Equivalence principle (Wikipedia, rev 1370775293, via Wikimedia Enterprise cache) (behind its links)
Einstein synchronisation (Wikipedia, rev 1372775708, via Wikimedia Enterprise cache) (behind its links)
Special relativity (Wikipedia, rev 1378669068, 2026-10-05, via Wikimedia Enterprise) (behind its links)
Proper reference frame (flat spacetime) (Wikipedia, rev 1373723201, via Wikimedia Enterprise cache) (behind its links)